Troubleshooting High-speed lifter

Lift Master three-phase motor specification

If a malfunction occurs, the causes and solutions are shown in the table below. Please shut off the power before inspecting.

1Doesn't work
2Works in reverse
3Operation is unstable
4slip down
5Poor stopping accuracy
6Abnormal noise and vibration occur

Lift Master servo motor specification

If a malfunction occurs, the causes and solutions are shown in the table below. Please shut off the power before inspecting.

*For servo motor drive types, please also refer to the motor manufacturer's Instruction Manuals.

7Doesn't work
8Operation is unstable
9Misalignment
10Abnormal noise and vibration occur
回答へ

Lift Master three-phase motor specification

1Doesn't work
Cause 1 No power Inspection method Check the power supply voltage Solution Connect the power circuit correctly
Cause 2 Poor connection of motor terminal block screws Inspection method Check for loose screws and disconnections Solution Ensure a secure connection
Return to list
2Works in reverse
Cause 1 The phase sequence of the power lines (U, V, W) is different Inspection method Check the phase sequence of the power lines (U, V, W). Solution Swap two of the power lines (U, V, W)
Return to list
3Operation is unstable
Cause 1 Overload, brake release Inspection method Check the connection status of power lines (U, V, W phases) Solution Fix any loose terminals
Return to list
4slip down
Cause 1 Brake malfunction Inspection method Check for brake operation noise Solution Please contact us
Inspection method Check for loose screws and disconnections Solution Ensure a secure connection
Return to list
5Poor stopping accuracy
Cause 1 Brake lining wear Inspection method Brake gap inspection Solution Adjust the brake gap
Return to list
6Abnormal noise and vibration occur
Cause 1 Loose bolts for fixing the main body Inspection method Check the installation status and check for loose bolts Solution Install correctly and tighten the fixing bolts securely.
Cause 2 Power supply Open phase Inspection method Measurement of power supply voltage (U, V, W) Solution Connect the power supply successfully
Return to list

Lift Master servo motor specification

7Doesn't work
Cause 1 No power Inspection method Check the power supply voltage Solution Connect the power circuit correctly
Cause 2 Overloaded Inspection method Test run without load Solution Reduce the load or change the motor capacity.
Cause 3 The servo amplifier and motor are not connected. Inspection method Check the connection of the power lines (U, V, W phases) Solution Set it up correctly
Cause 4 No speed/position command is input Inspection method Check the input signal Solution Enter the correct speed/position command
Cause 5 The servo-on signal remains off. Inspection method Check the servo-on signal Solution Turn on the servo-on signal
Cause 6 Command pulse mode selection is incorrect Inspection method Check the command pulse format Solution Set it up correctly
Cause 7 Forward drive inhibit and reverse drive inhibit input signals remain off. Inspection method Check the input signal Solution Turn on the input signal
Cause 8 Servo amplifier failure Inspection method Inspection of the internal circuit board Solution Replace the servo amplifier
Return to list
8Operation is unstable
Cause 1 Poor wiring connection Inspection method Check the connection status of the power lines (U, V, W phases) and signal line connectors Solution Fix loose terminals and connectors
Return to list
9Misalignment
Cause 1 Increased backlash in the reducer Inspection method Check for position deviation during positioning to the home position or a specified position Solution Overhaul required
Contact us
Cause 2 Servo motor or servo amplifier failure Inspection method Checking the operation of the motor alone
(Positioning) Check the amount of rotation
Solution Replace the servo motor and servo amplifier.
Return to list
10Abnormal noise and vibration occur
Cause 1 Loose bolts for fixing the main body Inspection method Check the installation status and check for loose bolts Solution Install correctly and tighten the fixing bolts securely.
Cause 2 Servo gain adjustment is insufficient Inspection method Check the servo gain Solution Adjusting the servo gain
Return to list