Power Cylinder Eco series CDS type
Power Cylinder Eco series servo type
*If a servo amplifier alarm occurs, refer to Instruction Manuals for the servo motor/amplifier you are using and take appropriate action.
| 1 |
Pressing the start button does not work |
| Cause 1 |
Wiring errors in the motor and control unit |
treatment |
Checking the wiring |
| Cause 2 |
Disconnection of motor stator windings and lead wires |
treatment |
Repairs and replacements |
| Cause 3 |
Electromagnetic switch or controller failure |
treatment |
repair |
| Cause 4 |
Large inertial load |
treatment |
Review of equipment design |
| Cause 5 |
Damage to the electronic components of the built-in controller |
treatment |
repair |
Return to list
| 2 |
The motor makes noise but does not move |
| Cause 1 |
Single-phase operation |
treatment |
Checking the wiring |
| Cause 2 |
Power supply voltage drop |
treatment |
Increase power supply capacity and consider power supply size |
| Cause 3 |
Brake electromagnet stroke is too large |
treatment |
exchange |
| Cause 4 |
Brake lining seizure |
treatment |
exchange |
Return to list
| 3 |
Rated thrust is not generated |
| Cause 1 |
Power supply voltage drop |
treatment |
Increase power supply capacity and consider power supply size |
| Cause 2 |
Connection failure of the other device |
treatment |
repair |
Return to list
| Cause 1 |
Excessive load |
treatment |
Load reduction and capacity considerations |
| Cause 2 |
Excessive use |
treatment |
Capacity considerations |
Return to list
| Cause 1 |
Impact load action |
treatment |
repair |
| Cause 2 |
Lateral load action |
treatment |
repair |
Return to list
| 6 |
Magnetic sensor does not output |
| Cause 1 |
Miswiring |
treatment |
Rewiring and sensor replacement |
| Cause 2 |
Overvoltage |
treatment |
Correct the power supply and replace the sensor |
Return to list
| 7 |
Pressing the start button does not work |
| Cause 1 |
Servo motor and amplifier wiring errors |
treatment |
Wiring inspection * |
| Cause 2 |
Servo amplifier alarm occurs |
treatment |
Check the alarm details and take action * |
| Cause 3 |
Servo motor/servo amplifier failure |
treatment |
Repairs and replacements |
| Cause 4 |
Overload and large inertial load |
treatment |
Review of equipment design |
| Cause 5 |
By the input signal of the servo amplifier |
treatment |
Check the input signal * |
| Cause 6 |
By parameter setting |
treatment |
Check the parameter settings * |
For details on the * marks, please refer to Instruction Manuals for the servo motor/amplifier you are using.
Return to list
| 8 |
The motor makes noise but does not move |
| Cause 1 |
Damage to the electromagnetic brake |
treatment |
exchange |
| Cause 2 |
Electromagnetic brake power supply failure |
treatment |
Check the brake power supply |
| Cause 3 |
Coupling slip |
treatment |
Check clamp bolt tightening |
| Cause 4 |
By the input signal of the servo amplifier |
treatment |
Check the input signal * |
| Cause 5 |
By parameter setting |
treatment |
Check the parameter settings * |
For details on the * marks, please refer to Instruction Manuals for the servo motor/amplifier you are using.
Return to list
| Cause 1 |
Servo motor and amplifier wiring errors |
treatment |
Wiring inspection * |
| Cause 2 |
Disconnection of the encoder cable or incorrect wiring |
treatment |
Wiring inspection * |
For details on the * marks, please refer to Instruction Manuals for the servo motor/amplifier you are using.
Return to list
| Cause 1 |
Servo motor and amplifier wiring errors |
treatment |
Wiring inspection * |
| Cause 2 |
By setting parameter gain |
treatment |
Check the parameter settings * |
For details on the * marks, please refer to Instruction Manuals for the servo motor/amplifier you are using.
Return to list
| 11 |
Rated thrust is not generated |
| Cause 1 |
Coupling slip |
treatment |
Tightening the clamp bolt |
| Cause 2 |
Connection failure of the other device |
treatment |
repair |
| Cause 3 |
Damage to the electromagnetic brake |
treatment |
exchange |
| Cause 4 |
Electromagnetic brake power supply failure |
treatment |
Check the brake power supply |
Return to list
| Cause 1 |
Excessive load |
treatment |
Load reduction and capacity considerations |
| Cause 2 |
Excessive use |
treatment |
Capacity considerations |
| Cause 3 |
Damage to the electromagnetic brake |
treatment |
exchange |
| Cause 4 |
Electromagnetic brake power supply failure |
treatment |
Check the brake power supply |
Return to list
| Cause 1 |
Impact load action |
treatment |
repair |
| Cause 2 |
Lateral load action |
treatment |
repair |
Return to list
| 14 |
Magnetic sensor does not output |
| Cause 1 |
Miswiring |
treatment |
Rewiring and sensor replacement |
| Cause 2 |
Overvoltage |
treatment |
Correct the power supply and replace the sensor |
Return to list