technical data Cable Carrier (CABLEVEYOR)-Flexible cable for Cable Carrier (CABLEVEYOR)- Technical Notes
Selection criteria
Cable selection table
| For control 200 Series |
For control and communication 400 Series |
For electric power 400 Series |
700 Series | S700C Series M700C Series |
|
|---|---|---|---|---|---|
| Maximum Allowable Acceleration | 10m/s2 | 20m/s2 | 20m/s2 | 50m/s2 | 50m/s2 |
| Maximum Allowable Speed (Short span) | 3.5m/s | 5m/s | 5m/s | 20m/s | 5m/s |
| Maximum Allowable Speed (Gliding arrangement) | 2m/s | 3.5m/s | 3.5m/s | 5m/s | 5m/s |
| travel distance Recommended use range | 25m | 100m | 100m | 500m | 50m |
| Operating temperature range | -5 ~ 80℃ | -5 ~ 80℃ | -5 ~ 80℃ | -35 ~ 90℃ | -35 ~ 90℃ |
| Minimum bending radius (No shield) | Cable outer diameter 10 times more | Cable outer diameter 7.5 times more | Cable outer diameter 7.5 times more | Cable outer diameter 7.5 times more | Depends on the type of cable |
| Minimum bending radius (Shielded) | Cable outer diameter 10 times more | Cable outer diameter 7.5 times more | Cable outer diameter 7.5 times more | Cable outer diameter 7.5 times more | Depends on the type of cable |
| cURus certified | ○ | ○ | ○ | ○ | ○ |
| UV resistance | Excellent | Excellent | Excellent | Yes (other colors) Yu (black sheath) | Yes (other colors) Yu (black sheath) |
| CFC-free | ○ | ○ | ○ | ○ | ○ |
| Flame retardant | ○ | ○ | ○ | ○ | ○ |
| Halogen-free | × | × | × | ○ | ○ |
| oil resistant | ○ | ○ | ○ | ○ | ○ |
| Silicone-free | ○ | ○ | ○ | ○ | ○ |
○: Supported ×: Not supported
Allowable current value
The allowable current (reference value) is when a maximum of three cores are loaded simultaneously at an ambient temperature (in the air) of 30°C, and when the cable is laid on the ground or earthed. For conditions with different temperatures and core number, multiply by the conversion factors in the ambient temperature correction factor table and the number of core number correction factor table (see DIN VDE 0298-4).
Allowable current (reference value)
| Nominal Cross-Sectional Area | sheath | ||
|---|---|---|---|
| PVC | PUR | PUR (single core) |
|
| 0.75mm2 | 12A | 15A | |
| 1mm2 | 15A | 19A | |
| 1.5mm2 | 18A | 23A | 24A |
| 2.5mm2 | 26A | 32A | 32A |
| 4mm2 | 34A | 42A | 42A |
| 6mm2 | 44A | 54A | 54A |
| 10mm2 | 61A | 75A | 73A |
| 16mm2 | 82A | 100A | 98A |
| 25mm2 | 108A | 127A | 141A |
| 35mm2 | 135A | 158A | 176A |
| 50mm2 | 168A | 192A | 216A |
| 70mm2 | 207A | 246A | 279A |
| 95mm2 | 250A | 298A | 342A |
| 120mm2 | 292A | 346A | 400A |
| 150mm2 | 335A | 399A | 464A |
| 185mm2 | 382A | 456A | 533A |
| 240mm2 | 453A | 538A | 634A |
| 300mm2 | 523A | 621A | 736A |
| 400mm2 | 868A | ||
| 500mm2 | 998A | ||
Note: 1. The values in the table are approximate and are abbreviated versions of DIN VDE 0298-4.
Note 2: All values are general guidelines and are not intended for any specific application.
Ambient temperature correction factor
| Ambient temperature °C | Maximum operating temperature range of the cable | |||
|---|---|---|---|---|
| 60℃ | 70℃ | 80℃ | 90℃ | |
| 10 | 1.29 | 1.22 | 1.18 | 1.15 |
| 15 | 1.22 | 1.17 | 1.14 | 1.12 |
| 20 | 1.15 | 1.12 | 1.10 | 1.08 |
| 25 | 1.08 | 1.06 | 1.05 | 1.04 |
| 30 | 1.00 | 1.00 | 1.00 | 1.00 |
| 35 | 0.91 | 0.94 | 0.95 | 0.96 |
| 40 | 0.82 | 0.87 | 0.89 | 0.91 |
| 45 | 0.71 | 0.79 | 0.84 | 0.87 |
| 50 | 0.58 | 0.71 | 0.77 | 0.82 |
| 55 | 0.41 | 0.61 | 0.71 | 0.76 |
| 60 | - | 0.50 | 0.63 | 0.71 |
| 65 | - | 0.35 | 0.55 | 0.65 |
| 70 | - | - | 0.45 | 0.58 |
| 75 | - | - | 0.32 | 0.50 |
| 80 | - | - | - | 0.41 |
| 85 | - | - | - | 0.29 |
core number correction factor
(Applicable to multi-core cables with a conductor nominal cross-sectional area of up to 10mm2)
| core number | When installed in the air Correction Factor |
|---|---|
| 5 | 0.75 |
| 7 | 0.65 |
| 10 | 0.55 |
| 14 | 0.50 |
| 19 | 0.45 |
| 24 | 0.40 |
| 40 | 0.35 |
| 61 | 0.30 |
Color Code
DIN 47100 color code table
| 1 white | 11 Gray-Pink | 21 White-Blue | 31 Green-Blue | 41 Gray-Black |
| 2 brown | 12 Red-Blue | 22 Brown-Blue | 32 Yellow-Blue | 42 Pink-Black |
| 3 Green | 13 White-Green | 23 White-Red | 33 Green-Red | 43 Blue-Black |
| 4 yellow | 14 Brown-Green | 24 Brown-Brown | 34 Yellow-Red | 44 Red-Black |
| 5 Gray | 15 white-yellow | 25 White-Black | 35 Green-Black | |
| 6 Pink | 16 Yellow-brown | 26 Brown-Black | 36 Yellow-Black | |
| 7 blue | 17 White-Brown | 27 Gray-Green | 37 Gray-Blue | |
| 8 Red | 18 Gray-Brown | 28 Yellow-Gray | 38 Pink-Blue | |
| 9 Black | 19 White-Pink | 29 Pink-Green | 39 Gray-Red | |
| 10 Purple | 20 Pink-Brown | 30 Yellow-Pink | 40 Pink-Red |
The first color represents the base color of the insulator, and the second color represents the base color of the print ring.
AWG conductor diameter and cross-sectional area
AWG (American Wire Gauge) Conversion Table
| AWG size | Diameter mm | Cross-sectional area mm 2 | AWG size | Diameter mm | Cross-sectional area mm 2 |
|---|---|---|---|---|---|
| 500 | 20.7 | 254 | 16 | 1.29 | 1.31 |
| 400 | 18.9 | 203 | 17 | 1.15 | 1.04 |
| 350 | 17.3 | 178 | 18 | 1.024 | 0.823 |
| 300 | 16.0 | 152 | 19 | 0.912 | 0.653 |
| 250 | 14.6 | 127 | 20 | 0.812 | 0.519 |
| 4/0 | 11.68 | 107.2 | 21 | 0.723 | 0.412 |
| 3/0 | 10.4 | 85 | 22 | 0.644 | 0.325 |
| 2/0 | 9.27 | 67.5 | 23 | 0.573 | 0.259 |
| 0 | 8.25 | 53.4 | 24 | 0.511 | 0.205 |
| 1 | 7.35 | 42.4 | 25 | 0.455 | 0.163 |
| 2 | 6.54 | 33.6 | 26 | 0.405 | 0.128 |
| 3 | 5.83 | 26.7 | 27 | 0.361 | 0.102 |
| 4 | 5.19 | 21.2 | 28 | 0.321 | 0.0804 |
| 5 | 4.62 | 16.8 | 29 | 0.286 | 0.0646 |
| 6 | 4.11 | 13.3 | 30 | 0.255 | 0.0503 |
| 7 | 3.67 | 10.6 | 31 | 0.227 | 0.04 |
| 8 | 3.26 | 8.366 | 32 | 0.202 | 0.032 |
| 9 | 2.91 | 6.63 | 33 | 0.18 | 0.0252 |
| 10 | 2.59 | 5.26 | 34 | 0.16 | 0.04 |
| 11 | 2.3 | 4.15 | 35 | 0.143 | 0.0161 |
| 12 | 2.05 | 3.3 | 36 | 0.127 | 0.0123 |
| 13 | 1.83 | 2.62 | 37 | 0.113 | 0.01 |
| 14 | 1.63 | 2.08 | 38 | 0.101 | 0.00795 |
| 15 | 1.45 | 1.65 | 39 | 0.0897 | 0.00632 |
The first color represents the base color of the insulator, and the second color represents the base color of the print ring.