technical data High-speed lifter Zip Chain Lifter Stroke Control

Stroke Control

Use the lifter within its "stroke".

(Stroke ≧ Used stroke)

Stroke Control

Position detection sensor specifications (ZSL1000)

Stroke adjustment limit switch
Manufacturer Omron Corporation
Limit switch type WLCA12-2-N (OMRON) equivalent product
Electrical capacity AC250V 10A (cosΦ=0.4)
DC5V 1mA (minimum applicable load)
Circuit configuration Circuit configuration
Connector (compatible cable outer diameter) SCS-10B (Φ8.5 to Φ10.5) PF1/2

Position detection sensor specifications (ZSL0050)

Lower deceleration/lower limit stop
Manufacturer Omron Corporation
Photomicrosensor EE-SPX303N
Input/Output Stage
Circuit Diagram
Dark ON time
chart
入出力段回路図
Output Circuit Output Circuit
Power Supply/Voltage DC12-24V±10% ripple (pp) 5% or less
Connection Method EE-1010 with 2M
Upper deceleration/upper limit stop
Manufacturer Omron Corporation
Photomicrosensor EE-SX672-WR
Input/Output Stage
Circuit Diagram
time
chart
Light ON Light ON Connection terminals
Connection terminals
Dark ON

Recommendation

Dark ON
Connection terminals
Connection terminals
Output Circuit Output Circuit
Power Supply/Voltage DC5-24V±10% Ripple (pp) 10% or less
Connection Method Cord pull-out type

*1 Do not short-circuit the L terminal to 0V when the light is off and the ON state is set.

Limit switch (LS) placement (ZSL1000)

ZSL1000

Limit switch (LS) placement (ZSL0050)

ZSL0050
Upper limit overrun and Lower limit overrun Stroke adjustment limit switch
Manufacturer Omron Corporation
Small Switch D2VW-5L1-1M
Contact Specifications Contact Specifications
Rated voltage AC250V Resistive load: 5A
AC125V Resistive load: 5A
DC30V Resistive load: 5A

The sensors marked with ★ in the limit switch layout diagram are only available with a three-phase motor. (There is no sensor in this position with a servo motor or motor with an encoder.) For details, please refer to the delivery drawing.

  • The upper and lower stroke limits are set by the upper and lower limit stop switches (LS). In case the upper and lower limit stop switches do not function effectively, upper and Lower limit overrun switches are provided.
  • - If the upper/lower Lower limit overrun sensor is activated, install an external brake circuit with DC external wiring and sequence circuit so that the lifter can be stopped by sudden braking. (If the lifter is raised or lowered at a speed faster than the maximum speed or the brake is switched to AC, the lifter will collide with the stopper, so this must be avoided. [This will cause a delay when braking, increasing the braking distance.]
    Additionally, the upper and lower limit stoppers are set as mechanical upper and lower limits. Never touch them. If they are loose or stopped halfway, the top plate frame may come into contact with them when lowering, which could result in damage to the equipment or a serious accident.
  • *If intermediate stops are required during lifter operation, please use a model with a rotary encoder or servo motor.