technical data Reducer Small Gear Motor Motor Specifications
Braking characteristics
1.Motor output: 0.1kW to 5.5kW
Gear Motor, Hypoid Motor, Croise Motor
| Motor Output | three phase | 0.1kW | 0.2kW | 0.4kW *0.55kW |
0.75kW | 1.5kW | 2.2kW | 3.7kW | 5.5kW |
|---|---|---|---|---|---|---|---|---|---|
| Brake model number | Three phase 200V | SLB01 | SLB02 | SLB04 | SLB07E | SLB15 | SLB22 | VNB371K NB-31190 | VNB55KE |
| Three phase 400V | SLB01 | SLB02 | SLB04V | SLB07E 180V | SLB15 180V | SLB22 180V | VNB371KV NB-31192 | VNB55KE | |
| DC rectifier model number | Three phase 200V | DM200D | DM200D | PM180B | |||||
| Three phase 400V | DM400D | ||||||||
| Rated Torque | Static friction torque N・m | 0.98 | 1.96 | 3.92 | 7.35 | 15 | 22 | 37 | 55 |
| {kgf・m} | 0.1 | 0.2 | 0.40 | 0.75 | 1.50 | 2.20 | 3.77 | 5.61 | |
| Dynamic friction torque N・m | 0.78 | 1.57 | 3.14 | 5.88 | 12.0 | 17.6 | 29.6 | 44 | |
| {kgf・m} | 0.08 | 0.16 | 0.32 | 0.60 | 1.20 | 1.79 | 3.02 | 4.48 | |
| Voltage | Three phase 200V | DC90V | DC90V | Instantaneous 180V Always 50V |
|||||
| Three phase 400V | DC180V | ||||||||
| current at 20℃ |
Three phase 200V | 0.178 | 0.178 | 0.232 | 0.273 | 0.289 | 0.289 | 0.261 | 0.253 |
| Three phase 400V | 0.142 | 0.145 | 0.145 | 0.135 | |||||
| capacity | at 20 ℃ W | 16.0 | 16.0 | 20.9 | 24.6/25.5 | 26.0/26.1 | 26.0/26.1 | 26.1/26.1 | 12.6/40.7 |
| Initial gap mm | 0.15 ~ 0.20 | 0.15 ~ 0.20 | 0.15 ~ 0.20 | 0.15 ~ 0.20 | 0.15 ~ 0.20 | 0.15 ~ 0.20 | 0.3 | 0.35 | |
| Limit gap mm | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 1.2 | 1.2 | |
| Moment of inertia kg m 2 | 0.02×10-3 | 0.04×10-3 | 0.04×10-3 | 0.11×10-3 | 0.21×10-3 | 0.50×10-3 | 0.50×10-3 | 1.70×10-3 | |
| GD2 kgf ・m2 | 0.10×10-3 | 0.15×10-3 | 0.15×10-3 | 0.44×10-3 | 0.80×10-3 | 2.00×10-3 | 2.00×10-3 | 6.8×10-3 | |
| Total braking work J {kgf・m} |
1.31×108 | 1.85×108 | 1.85×108 | 3.66×108 | 3.73×108 | 3.73×108 | 13.5×108 | 24.7×108 | |
| 1.34×107 | 1.89×107 | 1.89×107 | 3.73×107 | 3.81×107 | 3.81×107 | 13.8×107 | 25.2×107 | ||
| Allowable startup frequency | 10 times/minute | ||||||||
| Braking Delay Time S (reference value) |
AC internal wiring | 0.18 ~ 0.25 | 0.15 ~ 0.21 | 0.14 ~ 0.17 | 0.20 ~ 0.24 | 0.30 ~ 0.45 | 0.30 ~ 0.45 | 0.50 ~ 0.70 (0.40 ~ 0.60) |
- |
| AC external wiring | 0.11 ~ 0.18 | 0.09 ~ 0.12 | 0.06 ~ 0.09 | 0.10 ~ 0.13 | 0.10 ~ 0.13 | 0.10 ~ 0.13 | 0.20 ~ 0.40 | - | |
| AC external operation | 0.11 ~ 0.18 | 0.09 ~ 0.12 | 0.06 ~ 0.09 | 0.10 ~ 0.13 | 0.10 ~ 0.13 | 0.10 ~ 0.13 | 0.20 ~ 0.40 | 0.03 ~ 0.05 | |
| DC external wiring | 0.05 ~ 0.07 | 0.04 ~ 0.06 | 0.03 ~ 0.05 | 0.04 ~ 0.06 | 0.01 ~ 0.06 | 0.01 ~ 0.06 | - (0.02 ~ 0.04) |
- | |
- Note 1) The rated torque indicates the static friction torque and dynamic friction torque after fitting.
- Note 2) The braking delay time is a reference value and may vary depending on the brake condition, usage conditions, individual differences, etc. If you want to shorten the braking delay time (for lifting devices, etc.), we recommend DC external wiring.
- Note 3) Current and capacity are values at 200V/400V.
- Note 4) * indicates Croise Motor only.
- Note 5) For overseas shipments, please note that the above table may differ.
2.Motor output: 40W to 90W
Hypoid Motor mini series
| Motor Output | three phase | 40W | 60W | 90W | ||||
|---|---|---|---|---|---|---|---|---|
| Single phase | ||||||||
| Brake model number | three phase | BXW-04-10M-05-90V | BXW-04-10M-10-90V | |||||
| Single phase | ||||||||
| DC rectifier model number | three phase | DM200D | ||||||
| Single phase | DM100A | |||||||
| Rated Torque | Static Friction Torque N・m {kgf・m} |
0.6 {6.1} | 1.0 {10.2} | |||||
| Dynamic Friction Torque N・m {kgf・m} |
0.48 {4.8} | 0.8 {8.1} | ||||||
| Operating Voltage (V) | three phase | DC90V | ||||||
| Single phase | ||||||||
| Current (A) | three phase | 0.076 | 0.111 | |||||
| Single phase | ||||||||
| Capacity (W) | 6.8 | 10 | ||||||
| Gap Amount (mm) |
Initial value | 0.05~0.25 | ||||||
| Limit value (three-phase) | 0.4 | |||||||
| Limit value (single phase) | 0.3 | |||||||
| Total braking work J {kgf・m} |
three phase | 16.5×106 {16.8×105} | 13.4×106 {13.7×105} | |||||
| Single phase | 8.0×106 {8.16×105} | 7.1×106 {7.2×105} | ||||||
| Allowable startup frequency | 10 times/minute | |||||||
| Braking Delay Time S (reference value) |
AC internal wiring | 0.08 | 0.08 | |||||
| AC external wiring | 0.04 | 0.04 | ||||||
| AC external operation | 0.04 | 0.04 | ||||||
| DC external wiring | 0.01 | 0.01 | ||||||