technical data Cable Carrier (CABLEVEYOR)- Selecting Cable Carrier (CABLEVEYOR)- Points to note before selecting Cable Carrier (CABLEVEYOR)
Points to note before selecting Cable Carrier (CABLEVEYOR)
About cables and hoses
Cable and hose types
Use cables and hoses for transportation that are highly flexible and have excellent resistance to repeated bending and abrasion. Also, do not use Cable Carrier (CABLEVEYOR) and hoses with wire braid coverings, as sliding will damage both the cable carrier and the wire braid.
Allowable bending radius of cables and hoses
For the allowable bending radius of cables and hoses, please apply the value when they move (repeatedly articulate). Consult with the cable or hose manufacturer.
Reference: Please use the following as a guide.
■ In the case of cables
Allowable bending radius of the cable: r ≥ Cable outer diameter x 7.5 * (*Depending on cable type)
■ In the case of a hose
Allowable bending radius of the hose: r≧Outer diameter of the hose x 9 * (*Varies depending on hose type)
Please use a larger value if the cable or hose is used frequently, has high rigidity, or is a hydraulic hose.
Cable Carrier (CABLEVEYOR) bending radius
bending radius of Cable Carrier (CABLEVEYOR) should be larger than the allowable bending radius of the cables and hoses.The larger bending radius bending radius Cable Carrier (CABLEVEYOR) is, the more it will contribute to reducing wear on the cables and hoses and extending the life of the entire device, so select bending radius for Cable Carrier (CABLEVEYOR) that is as large as possible.
Cable Carrier (CABLEVEYOR) 's environmental resistance in various atmospheres
About temperature
Please refer to each product page for the operating temperature range. However, the service life may be shortened depending on the conditions of use. Also, in a low-temperature, humid atmosphere, Cable Carrier (CABLEVEYOR) may freeze and not bend smoothly. Forcing Cable Carrier (CABLEVEYOR) to operate in this state may damage it, so be sure to thoroughly remove any moisture from the frozen area before operating it.
Moisture and humidity
Generally, they can be used in atmospheric environments (including outdoors). However, in environments with high moisture content, high humidity, or exposed to wind and rain, we recommend replacing steel parts with stainless steel.
Outdoor installation (effects of ultraviolet rays)
Generally, it can be used outdoors. However, the "Cable Carrier (CABLEVEYOR) Plastic Series" deteriorates over time, so its lifespan may be shortened depending on the conditions and duration of use.
Cable Carrier (CABLEVEYOR) chemical resistance to various solutions
When selecting Cable Carrier (CABLEVEYOR), check the table below to see if the material has sufficient chemical resistance.
*This table shows the degree of material properties at 20°C, and does not represent the degree of guarantee. When actually using the product, please consider the temperature, humidity, and usage conditions comprehensively.
| Material/Solvent | steel | stainless | Engineering plastics | |||
|---|---|---|---|---|---|---|
| Standard products other than those listed on the right | TKP-MW specifications/TKR type | TKQ type side band | TKZP Series | |||
| acetone | △ | ○ | ○ | ○ | △ | △ |
| Oil (plant and mineral) | ○ | ○ | ○ | ○ | △ | △ |
| alcohol | ○ | ○ | ○ | ○ | △ | ○ |
| ammonia | △ | ○ | ○ | ○ | ○ | △ |
| calcium chloride aqueous solution | × | △ | ○ | - | ○ | △ |
| Sodium chloride | × | ○ | ○ | ○ | ○ | ○ |
| Hydrochloric acid (2%) | × | × | × | × | △ | △ |
| sea water | × | △ | ○ | △ | △ | △ |
| hydrogen peroxide | × | ○ | × | × | × | △ |
| Sodium hydroxide (10%) | × | ○ | ○ | ○ | ○ | ○ |
| Formic acid (10%) | × | ○ | △ | × | ○ | × |
| Citric acid (10%) | × | ○ | ○ | △ | ○ | × |
| Chromic acid (1%) | × | ○ | × | × | ○ | - |
| Acetic acid (5%) | × | ○ | ○ | ○ | △ | × |
| carbon tetrachloride | △ | ○ | ○ | ○ | △ | △ |
| Sodium hypochlorite (10%) | × | × | × | × | × | △ |
| Nitric acid (5%) | × | ○ | × | × | × | △ |
| lubricating oil | ○ | ○ | ○ | - | △ | △ |
| Potassium hydroxide | △ | ○ | ○ | ○ | ○ | ○ |
| soapy water | △ | ○ | ○ | - | ○ | △ |
| oil | ○ | ○ | ○ | - | - | × |
| diesel oil | ○ | ○ | ○ | - | - | × |
| toluene | ○ | ○ | ○ | ○ | - | △ |
| paraffin | ○ | ○ | ○ | ○ | - | - |
| benzene | ○ | ○ | ○ | × | △ | × |
| Iodine | × | × | × | × | × | × |
| sulfuric acid | × | × | × | × | × | △ |
| Phosphoric acid (10%) | × | △ | × | - | × | - |
| Vaseline | ○ | ○ | ○ | - | - | - |
Note) "Engineering plastic" refers to the engineering plastic (abbreviated as "enpla") material used in our Cable Carrier (CABLEVEYOR).
Cable Carrier (CABLEVEYOR) Plastic Series Flame Retardant Standards
The flame retardancy characteristics of our Cable Carrier (CABLEVEYOR) Plastic Series (TKP, TKR, TKUA, TKC, TKMK, TKMT) are based on the UL standard (Underwriters Laboratories Standards), which is a flame resistance safety test for plastic products, and the plastic material used is equivalent to UL94HB.