technical data linear actuator Zip Chain Actuator Hypoid Motor Motor Brake Characteristics
Hypoid Motor brake characteristics
1. ZCA35M・45M:0.2kW・0.4kW・0.75kW
| Hypoid Motor | ||||
|---|---|---|---|---|
| Motor Output | three phase | 0.2kW | 0.4kW | 0.75kW |
| Brake model number | Three phase 200V | SLB02 | SLB04 | SLB07E |
| Three phase 400V | SLB02 | SLB04V | SLB07E 180V | |
| DC rectifier model number | Three phase 200V | DM200D | ||
| Three phase 400V | DM200D | DM400D | ||
| Rated Torque | Static Friction Torque N・m{kgf・m} |
1.96{0.2} | 3.92{0.40} | 7.35{0.75} |
| Dynamic Friction Torque N・m{kgf・m} |
1.57{0.16} | 3.14{0.32} | 5.88{0.60} | |
| Voltage | Three phase 200V | DC90V | ||
| Three phase 400V | DC90V | DC180V | ||
| Current at 20℃ A | 0.178 | 0.232 | 0.273(0.142) | |
| Capacity at 20℃ W | 16 | 20.9 | 24.6(25.5) | |
| Initial gap mm | 0.15~0.20 | 0.15~0.20 | 0.15~0.20 | |
| Limit gap mm | 0.5 | 0.5 | 0.5 | |
| Total braking work J{kgf・m} | 1.85×108 {1.89×107} | 1.85×108 {1.89×107} | 3.66×108 {3.73×107} | |
| Allowable startup frequency | 10 times/minute | |||
| Braking Delay Time (Reference value) S |
AC internal wiring | 0.15~0.21 | 0.14~0.17 | 0.20~0.24 |
| AC external wiring | 0.09~0.12 | 0.06~0.09 | 0.10~0.13 | |
| AC external operation | 0.09~0.12 | 0.06~0.09 | 0.10~0.13 | |
| DC external wiring | 0.04~0.06 | 0.03~0.05 | 0.04~0.06 | |
- Note 1) The rated torque indicates the static friction torque and dynamic friction torque after fitting.
- Note 2) The braking delay time is a reference value and may vary depending on the brake condition, usage conditions, individual differences, etc. If you want to shorten the braking delay time (for lifting devices, etc.), we recommend DC external wiring.
2. ZCA25M:60W・90W
| Hypoid Motor mini series | |||
|---|---|---|---|
| Motor Output | three phase | 60W | 90W |
| Brake model number | three phase | BXW-04-10M-05-90V | BXW-04-10M-10-90V |
| DC rectifier model number | three phase | DM200D | |
| Rated Torque | Static Friction Torque N・m{kgf・cm} |
0.6{6.1} | 1.0{10.2} |
| Dynamic Friction Torque N・m{kgf・cm} |
0.48{4.8} | 0.8{8.1} | |
| Operating voltage (V) | three phase | DC90V | |
| Current (A) | three phase | 0.076 | 0.111 |
| Capacity (W) | 6.8 | 10 | |
| Gap Amount (mm) |
Initial value | 0.05~0.25 | |
| Limit value (three-phase) | 0.4 | ||
| Total braking work J{kgf・m} |
three phase | 16.5×106 {16.8×105} | 13.4×106 {13.7×105} |
| Allowable startup frequency | 10 times/minute | ||
| Braking Delay Time (Reference value) S |
AC internal wiring | 0.08 | 0.08 |
| AC external wiring | 0.04 | 0.04 | |
| AC external operation | 0.04 | 0.04 | |
| DC external wiring | 0.01 | 0.01 | |