technical data linear actuator Power Cylinder Motor Specifications

Terminal box specifications (U series, T series, G series)

Motor capacity: 0.1kW to 3.7kW

Terminal box shape Motor Capacity Connector Shape Applicable cable outer diameter Connector mounting dimension A Terminal box seat hole dimension B
0.4kW以下

(0.4kW or less)

0.1kW~0.4kW SK-14L Φ11~Φ13
{PF½}
-
0.75kW以上

(0.75kW or more)

0.75kW~1.5kW A20C Φ14~Φ15
{PF¾}
Φ28
2.2kW~3.7kW A25C Φ19~Φ20 G1
{PF1}
Φ35
  • Note)
    1. A rubber plug or plate is inserted inside the connector at the time of shipment to prevent water and other liquids from entering. Be sure to remove it before use. The ground terminal size is M4.
  • 2. When using a cabtyre cable or lead wire type outdoors, be sure to take adequate waterproofing measures.
  • 3. If you are considering a cable with a larger outer diameter than the applicable cable, please contact us.

Motor capacity: 5.5kW to 15kW

Terminal box shape Motor Capacity Connector mounting dimensions After M/G adapter conversion
Terminal box shape 5.5kW For motors 2×M32×1.5 G1
For brakes 1×M16×1.5
7.5kW For motors 2×M32×1.5 G1
For brakes 2×M16×1.5
11kW
15kW
For motors 2×M40×1.5
For brakes 2×M16×1.5
  • Note)
    1. The cable inlet of the terminal box has a metric thread. One "conversion adapter" that converts to a G thread is included for the motor and one for the brake.
  • 2. When using a cabtyre cable or lead wire type outdoors, be sure to take adequate waterproofing measures.
    *Connector specifications are also available. Please contact us for details.