technical data Mechanical protector TG Sensor Installation

  • The detection distance of the TG sensor is 2.0 mm for the AC type TGS12 and 1.5 mm for the DC type TGS8DN. Set the dimensions (s,t) in the table below with Shock Guard not tripped, and confirm that the TG sensor is in a non-detection state (the operation indicator light on the side is lit).
  • Next, trip Shock Guard. Then, while rotating the tripped Shock Guard by hand, confirm that the TG sensor is in the detection state (the operation indicator light on the side is off) and that there is no interference with the sensor plate, and then reset Shock Guard.

Installation diagram TGB08-16

Installation diagrams TGB08-16
Unit: mm
s t Sensor plate
amount of movement
AC type
TGS12
DC type
TGS08DN
TGB08-L, M, H 17.9 19.2 1.2 0.9
TGB12-L, M, H 21.8 22.7 1.0
TGB16-L, M, H 26.5 27.5 1.2

Installation Diagram TGB20-50

Installation diagram TGB20-50
Unit: mm
t Sensor plate
amount of movement
AC type
TGS12
DC type
TGS08DN
TGB20-H 2.0~3.8 2.0~3.2 1.8
TGB30-L, H 2.2~4.0 2.2~3.4 2.0
TGB50-L, M, H 2.9~4.7 2.9~4.1 2.7

Installation Diagram TGB70-130

Installation diagram TGB70-130
Unit: mm
t Sensor plate
amount of movement
AC type
TGS12
DC type
TGS08DN
TGB70-H 3.5~5.3 3.5~4.7 3.3
TGB90-L, H 5.6~7.4 5.6~6.8 5.4
TGB110-L, H 6.2~8.0 6.2~7.4 6.0
TGB130-L, H 6.8~8.6 6.8~8.0 6.6

Installation Diagram TGE17-50

Installation diagram TGE17-50
Unit: mm
s t Housing movement
AC type
TGS12
DC type
TGS08DN
TGE17 35.5 34 2.0~2.4 1.6
TGE25 48 2.4~2.8 2.0
TGE35 60 2.8~3.2 2.4
TGE50 80 3.6~4.0 3.2

Installation diagram TGX10-70

Installation diagrams TGX10-70
Unit: mm
s t Plate displacement
AC type
TGS12
DC type
TGS08DN
TGX10 28.8 29.9 1.2 1.4
TGX20 27.1 28.3 1.6
TGX35 28.2 29.5 2.0
TGX50 34.4 35.6 2.6
TGX70 33.4 34.5 3.5

Note)
The TG sensor, which is attached to Shock Guard can only be mounted in the radial direction, as shown in the left diagram.

Installation diagram TGX10-C to 70-C

Installation diagrams TGX10-C to 70-C
Unit: mm
s t Plate displacement
AC type
TGS12
DC type
TGS08DN
TGX10-C 36.5 2.1~3.3 2.1~2.8 1.3
TGX20-C 45 2.4~3.6 2.4~3.1 1.6
TGX35-C 59 2.7~3.9 2.7~3.4 1.9
TGX50-C 83 3.2~4.4 3.2~3.9 2.4
TGX70-C 105 4.1~5.3 4.1~4.8 3.3

Note)
For TG sensors attached to coupling-type systems, horizontal orientation is recommended, as shown in the left diagram.
Please contact us if you require radial mounting.

Installation Diagram TGF20-90

Installation diagram TGF20-90
Unit: mm
AC type TGS12
DC type TGS8DN
Housing movement
s t
TGF20 46 1.6~2.0 1.2
TGF30 60 2.2~2.6 1.8
TGF45 78 2.6~3.0 2.2
TGF65 100 3.1~3.5 2.7
TGF90 136 5.4~5.8 5.0