technical data High-speed lifter Lift Master Position Detection Sensor Specifications

Position detection sensor specifications

Model EE-SX972-C1(OMRON)
Power supply voltage DC 5 to 24 V ±10%
Ripple (pp) 10% or less
Control Output NPN open collector (load current 50mA or less)
Operation Mode OUT1: ON when light is received OUT2: ON when light is blocked
Electrical Circuit Electrical Circuit
[クリックで拡大]

For output specifications, PNP open collector type is also available as a special order, so please contact us for details.

When operating Lift Master in tandem (motor synchronization)

To start, turn on the power to all units at the same time, and to stop, use the position detection sensor attached to each Lift Master.

Avoid controlling all units with one position detection sensor as this will result in cumulative stroke errors.