1. Torque adjustment

Before shipment, we use our torque testing machine to measure the torque according to the setting specified by the customer. Therefore, there is no need to adjust the torque before initial use.

2. How to recover

2-1. When the adapter is the power source

Operating state

Recovery operation 1

Recovery operation 2

Insert the included key-type reset bar wrench into the turning hole of the adapter and rotate it in the same direction as the adapter's drive rotation (reset operation 1) until the slit positions of the drive plate and intermediate plate align.
Please rotate it.

Return operation 2 involves rotating the adapter in the drive-side rotation direction A until the slit positions of the drive plate and the intermediate plate align (random specification).

Recovery operation 3

Return operation completed

Next, insert the key (with magnet) from the included key-type reset bar wrench into the slits on the drive plate and the intermediate plate.

In this state, the key type resetting bar wrench can be turned in the direction that aligns the slit and the hole in the slide plate to reset it.

Remove the key-type reset wrench, and the reset process is complete.

2-2. When the main hub is the driving side

Operating state

Recovery operation 1

Recovery operation 2

Using the included key-type reset bar wrench, insert the turning hole of the torque adjustment nut into the same direction as the drive rotation of the main hub (reset operation 1) and adjust the slit positions of the drive plate and intermediate plate.
Rotate it until it matches.

Return operation 2 involves rotating the torque adjustment nut (main hub) in the drive side rotation direction B until the slit positions of the drive plate and intermediate plate align (random specification).

Recovery operation 3

Return operation completed

Next, insert the key (with magnet) from the included key-type reset bar wrench into the slits on the drive plate and the intermediate plate.

In this state, the key type resetting bar wrench can be turned in the direction that aligns the slit and the hole in the slide plate to reset it.

Remove the key-type reset wrench, and the reset process is complete.