technical data Mechanical protector (TL) - Maintenance
| item | TL | |
|---|---|---|
| Main unit | Precautions | Lubrication is not allowed. This is because when moisture or oil adheres to the friction plates, the coefficient of friction decreases, and the slip torque decreases. |
| Parts replacement | friction plate, bushing | |
| Parts replacement cycle | Friction plate: When the thickness becomes 1.25mm for TL200, and 1.6mm for TL250-700. | |
| Coupling section / Sprocket section | Is grease application necessary? | Essential |
| Maintenance target areas | Chain, sprocket | |
| Grease sealed inside at the time of shipment | - | |
| Recommended grease | Application of solid lubricant (molybdenum disulfide) | |
| Duration (approximate) | After installation and every 1000-2000 hours | |
| Sprocket maintenance | Check for sprocket wear | |