technical data Mechanical protector TGB Maintenance
| item | TGB Compact TGB08, TGB12, TGB16 |
TGB Medium (TGB20-TGB50) TGB Large (TGB70-TGB130) |
|
|---|---|---|---|
| Main unit | Target for grease application | Drive ball, thrust bearing | Drive ball, thrust bearing (TGB110, 130 have steel ball section) |
| Grease applied at the time of shipment | Cosmo Grease NEW Dynamax EP No.2 (Cosmo Oil Lubricants) | ||
| Recommended grease | • Mobilax EP2 (ExxonMobil Japan) - Shellgadas S2V220J2(EP) (Shell Lubricants Japan) ・Epinock Grease AP(N)2 (ENEOS) Daphne Grease MP No.2 (Idemitsu Kosan) Cosmo Grease NEW Dynamax EP No.2 (Cosmo Oil Lubricants) |
||
| Grease application cycle | Once per year or every 1000 trips | ||
| Coupling section / Sprocket section |
Is grease application necessary? | Unnecessary | Essential |
| Target for grease application | - | Chain, sprocket | |
| Grease sealed inside at the time of shipment | - | ||
| Recommended grease | - | - Same as the main unit Molybdenum disulfide |
|
| Grease application period (approximate) | - | Every 1000-2000 hours of operation | |
| Sprocket maintenance | - | Check for sprocket wear | |
The product names listed in the table above are trademarks or registered trademarks of their respective companies.